YANGDONG SERIES OPEN TYPE DIESEL GENERATOR
    Publish time 2021-07-30 11:52    
YANGDONG YD380D,YD480D,YND485D,YSD490D and etc engine;164D,184ES,184E,184F alternator;comap / deepsea / smartgen controller
YANGDONG SERIES OPEN TYPE DIESEL GENERATOR
{"0":{"title":"Product information","desc":"
Product Description

 DIESEL GENERATING.jpg

Control System

Support engine and alterantor monitoring,measurement and protection.

This is long-running and back-up unit to integrate the best way to control.

Support Modbus standard modem,RS232/RS485/USB and internet.

Engine

Advanced design and precise manufacturing ensure low fuel consumption.

Strong power and perfect low speed performance.

Excellent start performance Reliable running quality less spare parts involved provides easy maintenance and repair job.

Fuel injector and pump were tested fully in various environments which provide excellent.

Forklift holes

With base frame for lift hole and generator canopy lifting hole.

Fuel tank

Standard 8 hours generator running base frame fuel tank (100% load)

Alternator

Excellent design ensures compact structure and perfect appearance.

Excitation enhanced system improves start and short circuits protection performance.

Less parts involved and the most markets demand lead to cheap price and fine quality.

Core parts won t be involved in repair ob A R can be replaced easily examining diode doesnt disassemble rotor.



Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine  Alternator Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A model model model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG8K/KS 8.8  8.8  1.0  50  230  34.8  YD380D 164C ComAp IL9 3.5  68  1150×780×910 365  1680×760×1050 580
SDG10K/KS 10  10  11  11  1.0  50  230  43.5  YD480D 164D ComAp IL9 4.5  70  1560×900×980 480  1800×800×1140 665
SDG12K/KS 12  12  13.2  13.2  1.0  50  230  52.2  YND485D 184ES ComAp IL9 70  1560×900×980 490  1900×800×1140 730
SDG16K/KS 16  16  17.6  17.6  1.0  50  230  69.6  YSD490D 184E ComAp IL9 6.3  70  1560×900×980 505  1900×800×1140 760
SDG20K/KS 20  20  22  22  1.0  50  230  87  Y495D 184F ComAp IL9 7.8  70  1810×950×1020 650  1960×800×1140 820
SDG25K/KS 25  25  27.5  27.5  1.0  50  230  108.7  Y4102D 184H ComAp IL9 9.5  71  1810×950×1020 690  2200×1000×1320 1000
SDG38K/KS 30  30  33  33  1.0  50  230  130.4  Y4105D 184J ComAp IL9 10.8  71  1810×950×1020 770  2200×1000×1320 1045
SDG45K/KS 40  40  44  44  1.0  50  230  174  Y4102ZLD 224E ComAp IL9 14.2  72  1955×950×1360 945  2360×1000×1500 1200
SDG45K/KS 45  45  49.5  49.5  1.0  50  230  195.7  Y4105ZLD 224F ComAp IL9 16.1  72  1955×950×1360 995  2360×1000×1500 1250
SDG50K/KS 50  50  55  55  1.0  50  230  217.4  Y4EZLD 224F ComAp IL9 17.6  72  1955×950×1360 1035  2360×1000×1500 1290
SDG64K/KS 64  64  70  70  1.0  50  230  278.3  Y4110ZLD 274C ComAp IL9 19.6  72  2395×1000×1410 1140  2460×1000×1500 1530
Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine  Alternator Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW
HZ V A model model model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG10K/KS 10  11  8.8  0.8  50  400/230 14.4  YD380D 164B ComAp IL9 3.5  68  1150×780×910 365 1680×760×1050 580
SDG13K/KS 13.0  10  13.8  11  0.8  50  400/230 18.0  YD480D 164C ComAp IL9 4.5  70  1560×900×980 480 1800×800×1140 665
SDG15K/KS 15  12  16.5  13.2  0.8  50  400/230 21.7  YND485D 184ES ComAp IL9 70  1560×900×980 490 1900×800×1140 760
SDG20K/KS 20  16  22  17.6  0.8  50  400/230 28.9  YSD490D 184E ComAp IL9 6.3  70  1560×900×980 505 1900×800×1140 786
SDG25K/KS 25  20  27.5  22  0.8  50  400/230 36.1  Y495D 184F ComAp IL9 7.8  70  1810×950×1020 650 2200×950×1250 870
SDG31K/KS 31.0  25  34.4  27.5  0.8  50  400/230 45.2  Y4102D 184G ComAp IL9 9.5  71  1810×950×1020 690 2200×1000×1320 1000
SDG38K/KS 38  30  41  33  0.8  50  400/230 57.7  Y4105D 184J ComAp IL9 10.8  71  1810×950×1020 770 2200×1000×1320 1045
SDG50K/KS 50  40  55  44  0.8  50  400/230 86.6  Y4102ZLD 224D ComAp IL9 14.2  72  1955×950×1360 945 2360×1000×1420   1200
SDG56K/KS 56  45  61.6  49.5  0.8  50  400/230 86.6  Y4105ZLD 224E ComAp IL9 16.1  72  1955×950×1360 995  2360×1000×1420 1250 
SDG63K/KS 63  50  70  55  0.8  50  400/230 86.6  Y4EZLD 224E ComAp IL9 17.6  72  1955×950×1360 1035 2360×1000×1420 1290
SDG80K/KS 80  64  88  70  0.8  50  400/230 118.4  Y4110ZLD 224G ComAp IL9 19.6  72  2395×1000×1410 1140 2460×1000×1500 1530
SDG109KS 109  87  120  96  0.8  50  400/230 157.3  LR6A3L-DA 274D ComAp IL9 31.8  72  2550×1150×1560 1455 3000×1100×1700 2020
SDG145KS 145  116  160  128  0.8  50  400/230 209.3  LR6M3L-DA 274EL ComAp IL9 37.1  72  2550×1150×1560 1570 3300×1100×1700 2135
SDG181KS 181  146  200  160.2  0.8  50  400/230 262.7  YM6H4L-DA 274H ComAp IL9 50.6  72  2900×1300×1600 2000 3800×1500×2020 2650
SDG228K/KS 228  182  250  200  0.8  50  400/230 327.7  YM6S4L-DA 274J ComAp IL9 56.3  72  2900×1300×1600 2150 3800×1500×2020 2800
Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine  Alternator Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A model model model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG9K/KS 10.0  10.0  1.0  60  230  34.8  YD380D 164C ComAp IL9 3.9  68  1150×780×910 365  1680×760×1050 580
SDG11K/KS 11  11  12  12  1.0  60  230  43.5  YD480D 164D ComAp IL9 5.0  70  1560×900×980 480  1800×800×1140 665
SDG13K/KS 13  13  14.5  14.5  1.0  60  230  52.2  YND485D 184ES ComAp IL9 70  1560×900×980 490  1900×800×1140 730
SDG18K/KS 18  18  19.4  19.4  1.0  60  230  69.6  YSD490D 184E ComAp IL9 6.9  70  1560×900×980 505  1900×800×1140 760
SDG22K/KS 22  22  24  24  1.0  60  230  87  Y495D 184F ComAp IL9 8.6  70  1810×950×1020 650  1960×800×1140 820
SDG28K/KS 28  28  30.3  30.3  1.0  60  230  108.7  Y4102D 184H ComAp IL9 10.5  71  1810×950×1020 690  2200×1000×1320 1000
SDG33K/KS 33  33  36  36  1.0  60  230  130.4  Y4105D 184J ComAp IL9 11.9  71  1810×950×1020 770  2200×1000×1320 1045
SDG44K/KS 44  44  48  48  1.0  60  230  174  Y4102ZLD 224D ComAp IL9 15.6  72  1955×950×1360 945  2360×1000×1500 1200
SDG50K/KS 50  50  55.0  55.0  1.0  60  230  195.7  Y4105ZLD 224E ComAp IL9 17.7  72  1955×950×1360 995  2360×1000×1500 1250
SDG55K/KS 55  55  60  60  1.0  60  230  217.4  Y4EZLD 224F ComAp IL9 19.4  72  1955×950×1360 1035  2360×1000×1500 1290
Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine  Alternator Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A model model model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG11K/KS 11  12  9.7  0.8  60  440/254 14.4  YD380D 164B ComAp IL9 3.9  68  1150×780×910 365 1680×760×1050 580
SDG15K/KS 15.0  12  16.5  13  0.8  60  440/254 19.7  YD480D 164C ComAp IL9 5.0  70  1560×900×980 480 1800×800×1140 665
SDG17K/KS 17  14  18.7  15.0  0.8  60  440/254 22.3  YND485D 184ES ComAp IL9 70  1560×900×980 490 1900×800×1140 760
SDG22K/KS 22  18  24  19.4  0.8  60  440/254 28.9  YSD490D 184E ComAp IL9 6.9  70  1560×900×980 505 1900×800×1140 786
SDG28K/KS 28  22  30.8  25  0.8  60  440/254 36.7  Y495D 184F ComAp IL9 8.6  70  1810×950×1020 650 2200×950×1250 870
SDG34K/KS 34.0  27  37.4  29.9  0.8  60  440/254 44.6  Y4102D 184G ComAp IL9 10.5  71  1810×950×1020 690 2200×1000×1320 1000
SDG42K/KS 42  34  46  37  0.8  60  440/254 55.1  Y4105D 184J ComAp IL9 11.9  71  1810×950×1020 770 2200×1000×1320 1045
SDG55K/KS 55  44  61  48  0.8  60  440/254 72.2  Y4102ZLD 224D ComAp IL9 15.6  72  1955×950×1360 945 2360×1000×1420   1200
SDG63K/KS 63  50  69.3  55.4  0.8  60  440/254 82.7  Y4105ZLD 224E ComAp IL9 17.7  72  1955×950×1360 995  2360×1000×1420 1250 
SDG70K/KS 70  56  77  62  0.8  60  440/254 91.9  Y4EZLD 224E ComAp IL9 19.4  72  1955×950×1360 1035 2360×1000×1420 1290
SDG88K/KS 88  70  97  77  0.8  60  440/254 115.5  Y4110ZLD 224G ComAp IL9 21.6  72  2395×1000×1410 1140 2460×1000×1500 1530
SDG109KS 120  96  132  106  0.8  60  440/254 157.5  LR6A3L-DA 274D ComAp IL9 35.0  72  2550×1150×1560 1455 3000×1100×1700 2020
SDG145KS 160  128  176  141  0.8  60  440/254 210.0  LR6M3L-DA 274EL ComAp IL9 40.8  72  2550×1150×1560 1570 3300×1100×1700 2135
SDG181KS 200  160  220  176.0  0.8  60  440/254 262.4  YM6H4L-DA 274H ComAp IL9 55.7  72  2900×1300×1600 2000 3800×1500×2020 2650
SDG228K/KS 250  200  275  220  0.8  60  440/254 328.0  YM6S4L-DA 274J ComAp IL9 61.9  72  2900×1300×1600 2150 3800×1500×2020 2800


Genset Features
  • Compact structure high-strength chassis

  • Easy operation and maintenance, Low cost

  • Good performance damping system

  • Compliance with international electrical safety standards of electrical system

  • 8 hours base tank

  • High-performance maintenance-free batteries with isolation switch

  • 50 degrree radiator 

  • Forklift bottom hole design, easy to transport

  • Industrial type muffler

  • Noise reduction structure,Low overall noise

  • Convenient power output interface and ATS Interface

  • IP56 (control system)

  • The personalized design for user

Packaging & Shipping

 .jpg


Company Information

 banner 5.jpg

banner.jpg


Factory picture


1.jpg

2.jpg


Our partner


3.jpg


Product Warranty

Warranty Statement-1.jpg


Product Maintenance

Warranty Statement-2.jpg 

Before you buy

 Before you buy our generator sets,You should tell us…

 What is the situation for the power supplying there?

A .  Power supplying well, just about power supply bureau inspection, monthly that lead to power off in the hotel (or restaurant, bank, shop & store, etc.)

B.  Power supplying bad, power failure often

C.  No power supplying, such as in island or very wild field

What is the local voltage there?

A. 115/230V   B. 220V   C. 380V   D. 400V   E. 415V   F. 440V

What is the biggest power load should be for generator power                KW

Facilities for the generator, ventilation and smoke venting situation

Air intake and exhaust door                  A. Have          B. Without

Smoke venting pipe                               A. Have          B. Without

*Because bad air ventilation and smoke venting situation will lead to the generator overheated and adnormal work

What is the facilities the generator will be placed

A. Build a house for the generator outdoor

B. Basement of the big building

C. Installed with weatherproof canopy placed outdoor

D. With idea

Local government requirement for noise level

The generator will creat great noise if it isnt soundproof design type (you can buy soundproof type or build a soundproof house for the generator), youd better to realise area noise level requirement from local Environmental Protection Agency.

What is the ATS system?

If there is no person to start and stop the generator everytime, please buy ATS box, it will start and stop the generator automatically when mains supply (city power supplying ) off or on.

Automatic paralleling control system

If you must buy several units of generator for huge power load, we suggest you use our paralleling control system to provide enough power automatically.


"}}