CUMMINS SERIES SILENT TYPE DIESEL GENERATOR
    Publish time 2021-07-30 11:52    
CUMMINS 4B3.9-G2,4BT3.9-G2,4BTA3.9-G2,6BT5.9-G2 and etc engine;PI144G,UCI224D,UCDI274E alternator;comap / deepsea / smartgen controller
CUMMINS SERIES SILENT TYPE DIESEL GENERATOR
{"0":{"title":"Product information","desc":"
Product Description

 DIESEL GENERATING.jpg

Control System

Support engine and alterantor monitoring,measurement and protection.

This is long-running and back-up unit to integrate the best way to control.

Support Modbus standard modem,RS232/RS485/USB and internet.

Rainy canopy

Industrial waterproof canopy ensure generator all days running.

Industrial silencer (7 meters the noise is lower than 73 dB)

Engine

Advanced design and precise manufacturing ensure low fuel consumption.

Strong power and perfect low speed performance.

Excellent start performance Reliable running quality less spare parts involved provides easy maintenance and repair job.

Fuel injector and pump were tested fully in various environments which provide excellent.

Forklift holes

With base frame for lift hole and generator canopy lifting hole.

Fuel tank

Standard 8 hours generator running base frame fuel tank (100% load)

Alternator

Excellent design ensures compact structure and perfect appearance.

Excitation enhanced system improves start and short circuits protection performance.

Less parts involved and the most markets demand lead to cheap price and fine quality.

Core parts won t be involved in repair ob A R can be replaced easily examining diode doesnt disassemble rotor.



Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine Model Alternator Model  Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A cummins STAMFORD FARRAND model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG10DC/DCS 10  10  11  11  1.0  50  230 43.5  4B3.9-G1 PI044F 164C ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG12DC/DCS 12  12  13  13  1.0  50  230 52.2  4B3.9-G1 PI044G 164D ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG16DC/DCS 16  16  18  18  1.0  50  230 69.6  4B3.9-G1 PI144D 184ES ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG20DC/DCS 20  20  22  22  1.0  50  230 87.0  4B3.9-G1 PI144E 184E ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG20DC/DCS 20  20  22  22  1.0  50  230 87.0  4B3.9-G2 PI144F 184F ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG32DC/DCS 32  32  35  35  1.0  50  230 139.1  4BT3.9-G1 PI144J 184J ComAp IL9 9.3  70  1850×900×1331 860  2500×950×1500 1340 
SDG32DC/DCS 32  32  35  35  1.0  50  230 139.1  4BT3.9-G2 PI144J 184J ComAp IL9 9.3  70  1850×900×1331 860  2500×950×1500 1340 
SDG40DC/DCS 40  40  44  44  1.0  50  230 173.9  4BTA3.9-G2 UCI224 224D ComAp IL9 9.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG48DC/DCS 48  48  53  53  1.0  50  230 208.7  4BTA3.9-G2 UCI224E 224E ComAp IL9 9.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG64DC/DCS 64  64  70  70  1.0  50  230 278.3  6BT5.9-G1 UCI224F 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG64DC/DCS 64  64  70  70  1.0  50  230 278.3  6BT5.9-G2 UCI224F 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG67DC/DCS 67  67  74  74  1.0  50  230 291.3  6BT5.9-G1 UCI224G 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG67DC/DCS 67  67  74  74  1.0  50  230 291.3  6BT5.9-G2 UCI224G 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG80DC/DCS 80  80  88  88  1.0  50  230 347.8  6BT5.9-G1 UCI274C 274C ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG80DC/DCS 80  80  88  88  1.0  50  230 347.8  6BT5.9-G2 UCI274C 274C ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG91DC/DCS 91  91  100  100  1.0  50  230 395.7  6BTA5.9-G2 UCI274D 274D ComAp IL9 22  72  2350×1000×1480 1450  3400×1000×1700 1970 
SDG106DC/DCS 106  106  116  116  1.0  50  230 460.9  6BTAA5.9-G2 UCI274E DG274E ComAp IL9 30  72  2395×1000×1442 1550  3400×1000×1700 2080 
SDG127DC/DCS 127  127  140  140  1.0  50  230 552.2  6CTA8.3-G2 UCI274F 274F ComAp IL9 40  72  2550×1150×1560 1820  3650×1150×1920 2450 
SDG146DC/DCS 146  146  160  160  1.0  50  230 634.8  6CTA8.3-G2 UCI274G 274H ComAp IL9 40  72  2550×1150×1560 1820  3650×1150×1920 2450 
SDG160DC/DCS 160  160  176  176  1.0  50  230 695.7  6CTAA8.3-G2 UCI274H 274H ComAp IL9 51.4  72  2550×1150×1560 1860  3650×1150×1920 2480 
Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine Model Alternator Model  Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A cummins STAMFORD FARRAND model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG13DC/DCS 13  10  14  11  0.8  50  400/230 18.8  4B3.9-G1 S0L1-L 164C ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG15DC/DCS 15  12  16  13  0.8  50  400/230 21.7  4B3.9-G1 S0L1-P 164D ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG20DC/DCS 20  16  23  18  0.8  50  400/230 28.9  4B3.9-G1 S0L2-G 184ES ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG25DC/DCS 25  20  28  22  0.8  50  400/230 36.1  4B3.9-G1 S0L2-M 184E ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG25DC/DCS 25  20  28  22  0.8  50  400/230 36.1  4B3.9-G2 S0L2-M 184E ComAp IL9 6.4  70  1850×900×1331 840  2500×950×1500 1320 
SDG40DC/DCS 40  32  44  35  0.8  50  400/230 57.7  4BT3.9-G1 S1L2-K 184J ComAp IL9 9.3  70  1850×900×1331 860  2500×950×1500 1340 
SDG40DC/DCS 40  32  44  35  0.8  50  400/230 57.7  4BT3.9-G2 S1L2-K 184J ComAp IL9 9.3  70  1850×900×1331 860  2500×950×1500 1340 
SDG50DC/DCS 50  40  55  44  0.8  50  400/230 72.2  4BTA3.9-G2 S1L2-R 224D ComAp IL9 9.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG60DC/DCS 60  48  66  53  0.8  50  400/230 86.6  4BTA3.9-G2 S1L2-Y 224E ComAp IL9 9.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG80DC/DCS 80  64  88  70  0.8  50  400/230 115.5  6BT5.9-G1 UCI224F 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG80DC/DCS 80  64  88  70  0.8  50  400/230 115.5  6BT5.9-G2 UCI224F 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG83.75DC/DCS 84  67  93  74  0.8  50  400/230 121.2  6BT5.9-G1 UCI224G 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG83.75DC/DCS 84  67  93  74  0.8  50  400/230 121.2  6BT5.9-G2 UCI224G 224G ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG100DC/DCS 100  80  110  88  0.8  50  400/230 144.3  6BT5.9-G1 UCI274C 274C ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG100DC/DCS 100  80  110  88  0.8  50  400/230 144.3  6BT5.9-G2 UCI274C 274C ComAp IL9 22  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG115DC/DCS 115  91  125  100  0.8  50  400/230 164.5  6BTA5.9-G2 UCI274D 274D ComAp IL9 22  72  2350×1000×1480 1450  3400×1000×1700 1970 
SDG133DC/DCS 133  106  145  116  0.8  50  400/230 190.5  6BTAA5.9-G2 UCI274E DG274E ComAp IL9 30  72  2395×1000×1442 1550  3400×1000×1700 2080 
SDG150DC/DCS 150  127  175  140  0.8  50  400/230 229.5  6CTA8.3-G2 UCI274F 274F ComAp IL9 40  72  2550×1150×1560 1820  3650×1150×1920 2450 
SDG183DC/DCS 183  146  200  160  0.8  50  400/230 262.7  6CTA8.3-G2 UCI274G 274H ComAp IL9 40  72  2550×1150×1560 1820  3650×1150×1920 2450 
SDG200DC/DCS 200  160  220  176  0.8  50  400/230 288.7  6CTAA8.3-G2 UCI274H 274H ComAp IL9 51.4  72  2550×1150×1560 1860  3650×1150×1920 2480 
SDG228DC/DCS 228  182  251  201  0.8  50  400/230 329.1  6LTAA8. -G2 UCDI274J DG274J ComAp IL9 53 
2550×1150×1708 2150  3900×1300×2020 2810 
SDG250DC/DCS 250  200  275  220  0.8  50  400/230 360.9  6LTAA8. -G2 UCDI274K 274K ComAp IL9 53 
2550×1150×1708 2150  3900×1300×2020 2810 
SDG295DC/DCS 295  236  325  260  0.8  50  400/230 425.8  QSM11-G2 S4L1S-D 444D ComAp IL9 56 
2550×1150×1560 2550  3900×1300×2020 3150 
SDG328DC/DCS 328  262  360  288  0.8  50  400/230 472.0  QSM11-G2 S4L1S-E 444EL ComAp IL9 69 
2550×1150×1560 2650  3900×1300×2020 3250 
SDG350DC/DCS 350  280  385  308  0.8  50  400/230 505.2  NTA855-G2A S4L1S-E 444EL ComAp IL9 72 
2967×1150×1978 3250  4500×1463×2165 4130 
SDG375DC/DCS 375  300  413  330  0.8  50  400/230 541.3  NTA855-G7 S4L1S-F 444F ComAp IL9 86 
2967×1150×1978 3310  4500×1463×2165 4330 
SDG410DC/DCS 410  327  450  360  0.8  50  400/230 590.4  NTA855-G7A HCI544C 544C ComAp IL9 108 
2967×1150×1978 3450  4500×1463×2165 4530 
SDG455DC/DCS 455  364  500  400  0.8  50  400/230 656.8  KTA19-G3 HCI554C 544C ComAp IL9 97 
3400×1680×2055 3750  5050×1650×2475 4880 
SDG500DC/DCS 500  400  550  440  0.8  50  400/230 721.7  KTA19-G4 HCI544C 544D ComAp IL9 107 
3400×1680×2055 3780  5050×1650×2475 4940 
SDG568DC/DCS 568  454  625  500  0.8  50  400/230 819.9  KTA19-G5 HCI544E 544E ComAp IL9 113 
3400×1680×2055 3980  5050×1650×2475 5140 
SDG590DC/DCS 590  473  650  520  0.8  50  400/230 853.1  KTA19-G6 HCI544E 544E ComAp IL9 141.5 
3620×19200×2075 4500  5200×1790×2475 5940 
SDG620DC/DCS 620  494  680  544  0.8  50  400/230 892.0  KTA19-G6A HCI544FS 544FD ComAp IL9 150 
3620×19200×2075 4850  5200×1790×2475 6180 
SDG750DC/DCS 750  600  825  660  0.8  50  400/230 1082.6  KTA38-G2 LVI634B 634B ComAp IL9 167 
4380×2060×2397 7130  ISO 20ft container TBA
SDG800DC/DCS 800  640  880  704  0.8  50  400/230 1154.7  KTA38-G2B LVI634C 634C ComAp IL9 168 
4380×2060×2397 7510  ISO 20ft container TBA
SDG900DC/DCS 900  727  1000  800  0.8  50  400/230 1312.1  KTA38-G2A HCI634H 634D ComAp IL9 191 
4380×2060×2397 7920  ISO 20ft container TBA
SDG1000DC/DCS 1000  800  1100  880  0.8  50  400/230 1443.4  KTA38-G5 LVI634E 634E ComAp IL9 209 
4380×2060×2397 7930  ISO 20ft container TBA
SDG1250DC/DCS 1250  1000  1375  1100  0.8  50  400/230 1804.3  QSKTA38-G5 LVI634G 634G ComAp IL9 225 
4390×2040×2150 TBA ISO 20ft container TBA
SDG1273DC/DCS 1273  1018  1400  1120  0.8  50  400/230 1837.5  KTA50-G3 PI734B 734B ComAp IL9 261 
4390×2040×2150 TBA ISO 40ft container TBA
SDG1523DC/DCS 1523  1218  1675  1340  0.8  50  400/230 2198.3  KTA50-GS8 PI734C 734C ComAp IL9 289 
4390×2040×2150 TBA ISO 40ft container TBA


Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine Model Alternator Model  Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A cummins STAMFORD FARRAND model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG12DC/DCS 12  12  13  13  1.0  60  230 18.4  4B3.9-G2 S0L1-S DG164C ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG15DC/DCS 15  15  17  17  1.0  60  230 22.3  4B3.9-G2 S0L2-G DG164D ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG20DC/DCS 20  20  22  22  1.0  60  230 28.9  4B3.9-G2 S0L2-M DG184E ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG25DC/DCS 25  25  28  28  1.0  60  230 36.1  4B3.9-G2 S0L2-U DG184F ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG33DC/DCS 33  33  36  36  1.0  60  230 57.7  4BT3.9-G2 S1L2-K DG184H ComAp IL9 10.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG55DC/DCS 55  55  61  61  1.0  60  230 72.2  4BTA3.9-G2 UCI224E DG224E ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG66DC/DCS 66  66  73  73  1.0  60  230 86.6  4BTA3.9-G2 UCI224F DG224F ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG72DC/DCS 72  72  79  79  1.0  60  230 86.6  4BTA3.9-G11 UCI224G DG224G ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG84DC/DCS 84  84  92  92  1.0  60  230 115.5  6BT5.9-G2 UCI274C DG274C ComAp IL9 14.1  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG92DC/DCS 92  92  101  101  1.0  60  230 122.0  6BT5.9-G2 UCI274C DG274C ComAp IL9 25  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG100DC/DCS 100  100  110  110  1.0  60  230 144.3  6BT5.9-G2 UCI274D DG274D ComAp IL9 25  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG105DC/DCS 105  105  116  116  1.0  60  230 162.7  6BTA5.9-G2 UCI274E DG274E ComAp IL9 30  72  2350×1000×1480 1450  3400×1000×1700 1970 
SDG115DC/DCS 115  115  127  127  1.0  60  230 190.3  6BTAA5.9-G2 UCI274E DG274E ComAp IL9 34  72  2395×1000×1442 1550  3400×1000×1700 2080 
SDG128DC/DCS 128  128  141  141  1.0  60  230 190.3  6BTAA5.9-G12 UCI274F DG274F ComAp IL9 34  72  2395×1000×1442 1550  3400×1000×1700 2080 
Model Prime Power Standby Power Power Factor Frequency Rate Voltage Rate Current Engine Model Alternator Model  Controlller Fuel Consumption Sound @ 7 meter Open Type product size Open Type Weight net Canopy Type product size Canopy Type Weight net
KVA KW KVA KW HZ V A cummins STAMFORD FARRAND model L/Hours Db L*W*H(mm) KG L*W*H(mm) KG
SDG17DC/DCS 17  14  19  15  0.8  60  440/254 18.4  4B3.9-G2 S0L1-L FLD164C ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG20DC/DCS 20  16  22  18  0.8  60  440/254 22.3  4B3.9-G2 S0L1-P FLD164D ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG25DC/DCS 25  20  28  22  0.8  60  440/254 28.9  4B3.9-G2 S0L2-G FLD184ES ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG30DC/DCS 30  24  33  26  0.8  60  440/254 36.1  4B3.9-G2 S0L2-M FLD184F ComAp IL9 7.5  70  1850×900×1331 840  2500×950×1500 1320 
SDG42DC/DCS 42  34  46  37  0.8  60  440/254 57.7  4BT3.9-G2 S1L2-K FLD184H ComAp IL9 10.3  71  1850×900×1331 860  2500×950×1500 1340 
SDG64DC/DCS 64  51  70  56  0.8  60  440/254 72.2  4BTA3.9-G2 S1L2-Y FLD224E ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG75DC/DCS 75  60  83  66  0.8  60  440/254 86.6  4BTA3.9-G2 UCI224F FLD224F ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG90DC/DCS 90  72  99  79  0.8  60  440/254 86.6  4BTA3.9-G11 UCI224G FLD224G ComAp IL9 14.1  71  1850×900×1331 900  2500×950×1500 1380 
SDG105DC/DCS 105  84  116  92  0.8  60  440/254 115.5  6BT5.9-G2 UCI274C FLD274C ComAp IL9 14.1  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG115DC/DCS 115  92  127  101  0.8  60  440/254 122.0  6BT5.9-G2 UCI274C FLD274C ComAp IL9 25  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG125DC/DCS 125  100  138  110  0.8  60  440/254 144.3  6BT5.9-G2 UCI274D FLD274D ComAp IL9 25  72  2350×1000×1480 1300  3400×1000×1700 1820 
SDG131DC/DCS 131  105  144  115  0.8  60  440/254 162.7  6BTA5.9-G2 UCI274D FLD274D ComAp IL9 30  72  2350×1000×1480 1450  3400×1000×1700 1970 
SDG145DC/DCS 145  116  160  128  0.8  60  440/254 190.3  6BTAA5.9-G2 UCI274E FLD274DL ComAp IL9 34  72  2395×1000×1442 1550  3400×1000×1700 2080 
SDG160DC/DCS 160  128  176  141  0.8  60  440/254 190.3  6BTAA5.9-G12 UCI274E FLD274E ComAp IL9 34  72  2395×1000×1442 1550  3400×1000×1700 2080 
SDG190DC/DCS 190  152  209  167  0.8  60  440/254 259.8  6CTA8.3-G2 UCI274F FLD274F ComAp IL9 45  72  2550×1150×1560 1820  3650×1150×1920 2450 
SDG210DC/DCS 210  168  231  185  0.8  60  440/254 288.7  6CTAA8.3-G2 UCI274G FLD274G ComAp IL9 51  72  2550×1150×1560 1860  3650×1150×1920 2480 
SDG260DC/DCS 260  208  286  229  0.8  60  440/254 328.0  6LTAA8.9-G2 UCDI274J FLD274J ComAp IL9 45  72  2550×1150×1560 1860  3650×1150×1920 2480 
SDG280DC/DCS 280  224  308  246  0.8  60  440/254 360.9  6LTAA8.9-G3 UCDI274J FLD274J ComAp IL9 58  72  2550×1150×1708 2150  3900×1300×2020 2810 
SDG313CC/CCS 313  250  344  275  0.8  60  440/254 511.8  NTA855-G1 S4L1S-D FLD444D ComAp IL9 87.0  72  2967×1150×1978 3250  4500×1463×2165 4130 
SDG323CC/CCS 323  258  355  284  0.8  60  440/254 511.8  NTA855-G1B S4L1S-D FLD444D ComAp IL9 87  72  2967×1150×1978 3250  4500×1463×2165 4130 
SDG394CC/CCS 394  315  433  347  0.8  60  440/254 511.8  NTA855-G3 S4L1S-E FLD444E ComAp IL9 87  72  2967×1150×1978 3250  4500×1463×2165 4130 
SDG435CC/CCS 435  348  479  383  0.8  60  440/254 570.8  KTA19-G2 S4L1D-E FLD444F ComAp IL9 98  72  3400×1680×2055 3750  5050×1650×2475 4880 
SDG513CC/CCS 513  410  564  451  0.8  60  440/254 669.2  KTA19-G3 S4L1D-G FLD544C ComAp IL9 111  72  3400×1680×2055 3750  5050×1650×2475 4910 
SDG563CC/CCS 563  450  619  495  0.8  60  440/254 734.8  KTA19-G3A HCI544D FLD544D ComAp IL9 122  72  3400×1680×2055 3780  5050×1650×2475 4940 
SDG588CC/CCS 588  470  647  517  0.8  60  440/254 767.6  KTAA19-G5 HCI544D FLD544D ComAp IL9 134  72  3400×1680×2055 3980  5050×1650×2475 5140 
SDG750SCC/CCS

750  600  0.8  60  440/254 892.3  KTAA19-G6A HCI544E FLD544E ComAp IL9 140  72  3620×19200×2075 4850  5200×1790×2475 6180 
SDG775CC/CCS 775  620  853  682  0.8  60  440/254 1017.0  KT38-G HCI544F FLD544F ComAp IL9 180  72  4380×2060×2397 6980  ISO20ftcontainer TBA
SDG875CC/CCS 875  700  963  770  0.8  60  440/254 1181.0  KTA38-G1 HCI634G FLD634C ComAp IL9 204  72  4380×2060×2397 7130  ISO20ftcontainer TBA
SDG906CC/CCS 906  725  997  797  0.8  60  440/254 1312.2  KTA38-G2 HCI634G FLD634C ComAp IL9 225  72  4380×2060×2397 7920  ISO20ftcontainer TBA
SDG938CC/CCS 938  750  1032  825  0.8  60  440/254 1312.2  KTA38-G2B HCI634H FLD634D ComAp IL9 225  72  4380×2060×2397 7920  ISO20ftcontainer TBA
SDG1000CC/CCS 1000  800  1100  880  0.8  60  440/254 1312.2  KTA38-G2A HCI634H FLD634D ComAp IL9 225  72  4380×2060×2397 7920  ISO20ftcontainer TBA
SDG1125CC/CCS 1125  900  1238  990  0.8  60  440/254 1476.2  KTA38-G4 HCI634J FLD634F ComAp IL9 250.0  72  4380×2060×2397 8120  ISO20ftcontainer TBA
SDG1200CC/CCS 1200  960  1320  1056  0.8  60  440/254 1640.2  QSK38-G5 HCI634J FLD634F ComAp IL9 255  72  4390×2040×2150 TBA ISO20ftcontainer TBA
SDG1375CC/CCS 1375  1100  1513  1210  0.8  60  440/254 1640.2  QSK38-G4 PI734A FLD634G ComAp IL9 255  72  4390×2040×2150 TBA ISO20ftcontainer TBA
SDG1375SCC/CCS 1250  1000  1375  1100  0.8  60  440/254 1640.2  KTA38-G9 HCI634K FLD634F ComAp IL9 280  72  4380×2060×2397 8250  ISO20ftcontainer TBA
SDG1375CC/CCS 1375  1100  1575  1260  0.8  60  440/254 1804.3  KTA50-G3 PI734A FLD634G ComAp IL9 310  72  5800×2040×2150 TBA ISO40ftcontainer TBA
SDG1575CC/CCS 1575  1260  1733  1386  0.8  60  440/254 2047.0  KTA50-G9 PI734C DG734C ComAp IL9 350  72  5800×2040×2150 TBA ISO40ftcontainer TBA


Genset Features
  • Compact structure high-strength chassis

  • Easy operation and maintenance, Low cost

  • Good performance damping system

  • Compliance with international electrical safety standards of electrical system

  • 8 hours base tank

  • High-performance maintenance-free batteries with isolation switch

  • 50 degrree radiator 

  • Forklift bottom hole design, easy to transport

  • Industrial type muffler

  • Noise reduction structure,Low overall noise

  • Convenient power output interface and ATS Interface

  • IP56 (control system)

  • The personalized design for user

Packaging & Shipping

 .jpg


Company Information

 banner 5.jpg

banner.jpg


Factory picture


1.jpg

2.jpg


Our partner


3.jpg


Product Warranty

Warranty Statement-1.jpg


Product Maintenance

Warranty Statement-2.jpg 

Before you buy

 Before you buy our generator sets,You should tell us…

 What is the situation for the power supplying there?

A .  Power supplying well, just about power supply bureau inspection, monthly that lead to power off in the hotel (or restaurant, bank, shop & store, etc.)

B.  Power supplying bad, power failure often

C.  No power supplying, such as in island or very wild field

What is the local voltage there?

A. 115/230V   B. 220V   C. 380V   D. 400V   E. 415V   F. 440V

What is the biggest power load should be for generator power                KW

Facilities for the generator, ventilation and smoke venting situation

Air intake and exhaust door                  A. Have          B. Without

Smoke venting pipe                               A. Have          B. Without

*Because bad air ventilation and smoke venting situation will lead to the generator overheated and adnormal work

What is the facilities the generator will be placed

A. Build a house for the generator outdoor

B. Basement of the big building

C. Installed with weatherproof canopy placed outdoor

D. With idea

Local government requirement for noise level

The generator will creat great noise if it isnt soundproof design type (you can buy soundproof type or build a soundproof house for the generator), youd better to realise area noise level requirement from local Environmental Protection Agency.

What is the ATS system?

If there is no person to start and stop the generator everytime, please buy ATS box, it will start and stop the generator automatically when mains supply (city power supplying ) off or on.

Automatic paralleling control system

If you must buy several units of generator for huge power load, we suggest you use our paralleling control system to provide enough power automatically.


"}}